    Hoc systema destinatur ad NMP e processu fabricationis electrodorum secundariorum accumulatorum lithium-ionicorum recirculandum. Aer calidus solvente onustus e furnis in Systema Recuperationis NMP DRYAIR trahitur, ubi NMP per combinationem condensationis et adsorptionis recuperatur. Aer purgatus solvente onustus praesto est ad reddendum ad processum vel ad emittendum in atmosphaeram secundum requisita emptoris. NMP significat N-Methyl-2-Pyrrolidone, solvens carum est. Praeterea, recuperatio et recirculatio NMP sumptus operationis pro officinis accumulatorum lithium reducere potest necnon pollutionem aeris vitare.

    Proprietates:

    Ratio recuperationis 97%

    Emissio NMP: 12ppm

    Concentratio Solventis NMP recuperati: 85%

    Sectio functionalis:

    Commutator Caloris, Refrigerator

    Concentrator VOC, Ventilator Processus

    Receptaculum Solventis (ad libitum)

    Siemens PLC

     

     

     

    Systema Recuperationis NMP Seriei ZJRH

    Res

    ZJRH-D30-9000

    ZJRH-D50-15000

    ZJRH-D60-20000

    ZJRH-D75-25000

    ZJRH-D90-30000

    ZJRH-D120-40000

    Volumen aeris processus CMH

    9000

    Quindecim milia

    Viginti milia

    25000

    Tria milia

    Quadringenta milia

    Concentratio NMP in aere exhausto emissu

    ≤50mg/m³

    Concentratio solventis NMP recuperati

    ≥85%

    Ratio recuperationis NMP

    ≥97%

    Permutator caloris

    efficientia ≥65%

    Refrigeratorium #1 kW (aqua refrigerans ≤32℃)

    38

    63

    84

    105

    126

    CLXVIII

    Refrigeratorium #2 kw (aqua refrigerata ≤10℃)

    33

    55.8

    74

    93

    116

    149

    Ventilator processus #1 kW

    5.5

    11

    15

    15

    18.5

    22

    Ventilator processus #2 kW

    3

    5.5

    7.5

    7.5

    11

    15

    Motor ventilatoris reactivationis KW

    2.2

    2.2

    3

    3

    4

    4

    Potentia calorica reactivationis kW

    12

    18

    22.5

    27

    36

    48

    Potentia aestimata kW

    22.7

    36.7

    48

    52.5

    69.5

    89