Manufacturer for Battery Dry Room - ZJEN SERIES VOC Abatement System – Dry Air

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We now have several exceptional workers customers good at marketing, QC, and working with types of troublesome trouble during the creation system for Walk-In Temperature And Humidity Control Room, Electric Heater Cool Air Dehumidifier, Home Used Air Dehumidifier, And we are able to enable on the lookout for any products with the customers' needs. Make sure deliver the best Assistance, the most beneficial High-quality, The quickly Delivery.
Manufacturer for Battery Dry Room - ZJEN SERIES VOC Abatement System – Dry Air Detail:

1

Product advantages of VOC Concentrating rotor+Molecular Sieve rotor system

1. Processing efficiency of molecular sieve rotor is up to 95% and life span is up to 10 years.

2. High economic efficiency:high purity of the recovery solvent and it can be directly used in the production,

3.High safety, it can make up the deficiency of explosiveness of RTO equipment and in flammabilityof active carbon filter unit at high temperature.

2

High concentration exhaust:Deep condensation+RTO(Regenerative Thermal Oxidizer)/CO 

Working Principle

3

High concentration exhaust is deeply cooled down to -20℃ to -75℃so that the organic waste gas is condensed into a liquid state and recycled. The pollutant in VOC laden air stream is destroyed and converted into carbon dioxide, heat and water at 800  by a RTO burner to meet emission standards. 

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Rated power

(kw)

Recovery rate(%)

JEN-RH-200-L35E

100-300

5*3.2*3.2

10-15

15

≥95

JEN-RH-400-L35E

300-500

7*3.2*3.2

15-20

30

≥95

JEN-RH-600-L35E

500-700

10*3.2*3.2

25-30

45

≥95

JEN-RH-800-L35E

700-900

10*3.2*3.3

25-30

60

≥95

Note

  1. Discharge to meet local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, low concentration exhaust: VOC Concentrating rotor+Molecular Sieve rotor

 

Working Principle :

 Large volume, low concentration exhaust   is cooled down by pre-cooler and further processed by a VOC concentrating rotor.The purified air is discharged to the atmosphere through a main exhaust fan.

The moisture in the concentrated and desorbed exhaust gas is removed by cooling coils and a molecular sieve rotor, the temperature of  the exhaust air is cooled down by a heat exchanger and condenser. The condensed air directed to the low-temperature side and recycled as reactivation air of the molecular sieve rotor.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Installed power

(kw)

Removal rate

(%)

ZJEN-H-8000-L35E

7000-9000

6*6*4

10

75

≥97

ZJEN-H-15000-L35E

14000-16000

8*8*4

11

100

≥97

ZJEN-H-20000-L35E

18000-22000

8*8*4

12

150

≥97

ZJEN-H-25000-L35E

23000-27000

12*9*6

13

180

≥97

ZJEN-H-30000-L35E

28000-32000

13*9*6

14

225

≥97

ZJEN-H-40000-L35E

38000-43000

14*10*6

15

300

≥97

ZJEN-H-50000-L35E

48000-52000

14*10*6

16

375

≥97

Note

  1. Discharge to meet the local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, medium concentration exhaust :Active Carbon filter+VOC Concentrating rotor

Principle introduction:

Exhaust gas with concentration of 2200mg/m3 is processed by GAC activated carbon filter device and a zeolite VOC adsorption rotor where it purified to  70mg/m3.

The solvent in the activated carbon filter device is condensed and recycled.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(ton)

Rated power

(kw)

Moisture content

(%)

ZJEN-H-10000-E

6000-15000

7*7*4

20

50

≤1

ZJEN-H-20000-E

16000-25000

9*9*4

22

100

≤1

ZJEN-H-30000-E

26000-35000

10*8*4

24

150

≤1

ZJEN-H-40000-E

36000-45000

10*8*4

26

200

≤1

Remark

1.Emission concentration ≤ 70mg / m3 to meet local emission standards2.Reactivation source is 180℃ heat conduction oil.

 


Product detail pictures:

Manufacturer for Battery Dry Room - ZJEN SERIES VOC Abatement System – Dry Air detail pictures


Related Product Guide:
working principle of dehumidifier
How to Choose a Dehumidifier

We also offer you product sourcing and flight consolidation expert services. We've our personal manufacturing unit and sourcing business. We can offer you virtually every variety of merchandise associated to our item range for Manufacturer for Battery Dry Room - ZJEN SERIES VOC Abatement System – Dry Air , The product will supply to all over the world, such as: Brasilia, San Diego, Algeria, To have much more enterprise. ompanions, we've got updated the item list and seek for optimistic co-operation. Our web-site shows the latest and complete information and facts about our goods list and company. For further acknowledge, our consultant service group in Bulgaria will reply to all of the inquiries and complications immediately. They're going to make their finest effort to meet buyers need. Also we support the delivery of absolutely free samples. Business visits to our business in Bulgaria and factory are generally welcome for a win-win negotiation. Hope to expertise a happy company co-operation perform with you.
  • In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By Martin Tesch from Liverpool - 2018.06.19 10:42
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Mario from Johor - 2018.09.29 13:24
    Write your message here and send it to us