High reputation dry240ec – Industrial Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air

Short Description:

Product advantages of VOC Concentrating rotor+Molecular Sieve rotor system: 1. Processing efficiency of molecular sieve rotor is up to 95% and life span is up to 10 years. 2. High economic efficiency:high purity of the recovery solvent and it can be directly used in the production, 3.High safety, it can make up the deficiency of explosiveness of RTO equipment and in flammabilityof active carbon filter unit at high temperature. High concentration exhaust:Deep condensation+RTO(Regenerative ...


Product Detail

Product Tags

Related Video

Feedback (2)

Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Newest Dehumidifier, Calcium Chloride Dehumidifier, China Refrigetative Dehumidifier, Our company is working through the procedure principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a pleasant relationship with businessman from all around the earth.
High reputation dry240ec – Industrial Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air Detail:

1

Product advantages of VOC Concentrating rotor+Molecular Sieve rotor system

1. Processing efficiency of molecular sieve rotor is up to 95% and life span is up to 10 years.

2. High economic efficiency:high purity of the recovery solvent and it can be directly used in the production,

3.High safety, it can make up the deficiency of explosiveness of RTO equipment and in flammabilityof active carbon filter unit at high temperature.

2

High concentration exhaust:Deep condensation+RTO(Regenerative Thermal Oxidizer)/CO 

Working Principle

3

High concentration exhaust is deeply cooled down to -20℃ to -75℃so that the organic waste gas is condensed into a liquid state and recycled. The pollutant in VOC laden air stream is destroyed and converted into carbon dioxide, heat and water at 800  by a RTO burner to meet emission standards. 

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Rated power

(kw)

Recovery rate(%)

JEN-RH-200-L35E

100-300

5*3.2*3.2

10-15

15

≥95

JEN-RH-400-L35E

300-500

7*3.2*3.2

15-20

30

≥95

JEN-RH-600-L35E

500-700

10*3.2*3.2

25-30

45

≥95

JEN-RH-800-L35E

700-900

10*3.2*3.3

25-30

60

≥95

Note

  1. Discharge to meet local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, low concentration exhaust: VOC Concentrating rotor+Molecular Sieve rotor

 

Working Principle :

 Large volume, low concentration exhaust   is cooled down by pre-cooler and further processed by a VOC concentrating rotor.The purified air is discharged to the atmosphere through a main exhaust fan.

The moisture in the concentrated and desorbed exhaust gas is removed by cooling coils and a molecular sieve rotor, the temperature of  the exhaust air is cooled down by a heat exchanger and condenser. The condensed air directed to the low-temperature side and recycled as reactivation air of the molecular sieve rotor.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Installed power

(kw)

Removal rate

(%)

ZJEN-H-8000-L35E

7000-9000

6*6*4

10

75

≥97

ZJEN-H-15000-L35E

14000-16000

8*8*4

11

100

≥97

ZJEN-H-20000-L35E

18000-22000

8*8*4

12

150

≥97

ZJEN-H-25000-L35E

23000-27000

12*9*6

13

180

≥97

ZJEN-H-30000-L35E

28000-32000

13*9*6

14

225

≥97

ZJEN-H-40000-L35E

38000-43000

14*10*6

15

300

≥97

ZJEN-H-50000-L35E

48000-52000

14*10*6

16

375

≥97

Note

  1. Discharge to meet the local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, medium concentration exhaust :Active Carbon filter+VOC Concentrating rotor

Principle introduction:

Exhaust gas with concentration of 2200mg/m3 is processed by GAC activated carbon filter device and a zeolite VOC adsorption rotor where it purified to  70mg/m3.

The solvent in the activated carbon filter device is condensed and recycled.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(ton)

Rated power

(kw)

Moisture content

(%)

ZJEN-H-10000-E

6000-15000

7*7*4

20

50

≤1

ZJEN-H-20000-E

16000-25000

9*9*4

22

100

≤1

ZJEN-H-30000-E

26000-35000

10*8*4

24

150

≤1

ZJEN-H-40000-E

36000-45000

10*8*4

26

200

≤1

Remark

1.Emission concentration ≤ 70mg / m3 to meet local emission standards2.Reactivation source is 180℃ heat conduction oil.

 


Product detail pictures:

High reputation dry240ec – Industrial Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air detail pictures


Related Product Guide:
working principle of dehumidifier
Eva Dry EDV 1100 Electric Petite Dehumidifier Product Overview

That has a sound business enterprise credit rating, exceptional after-sales provider and modern producing facilities, we now have earned an superb standing amongst our buyers across the world for High reputation dry240ec – Industrial Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air, The product will supply to all over the world, such as: Jamaica, Atlanta, Roman, With the technology as the core, develop and produce high-quality merchandise according to the diverse needs of the market. With this concept,the company will continue to develop merchandise with high added values and continuously improve items,and will present many customers with the best goods and services!
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Pearl Permewan from Wellington - 2017.06.25 12:48
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Mario from Anguilla - 2018.09.12 17:18
    
    WhatsApp Online Chat !